Description
Harman 450 Watt Igniter for units with pressurized ignition, to include: PC45, HF60, PF100, and PB1050. This part was formerly known as 3-20-00450.
The most common reason for this igniter to burn out is poor airflow through the ignition pump, 3-20-02679. This will result in longer than normal ignition times or faulty start-ups. If the pump is very loud, replace the pump.
The igniter requires air to cool the igniter after the stove has ignited. If the intake filter is clogged, clean it in warm water or replace it, 1-00-02679. Reinstall the filter and see if the pump is moving air.
Replacement For Part Numbers:
- 1-00-10450
- 3-20-00450
View Compatible Models
UPC:652174686025